The Dynaco M2 FREEZER Door is designed for interior and exterior environments where cold storage with negative temperatures to as low as -22°F are required. The door comes with an automatic cycle mode to maintain door operation in freezer applications. The control box should be mounted on the warm side, but optional cold side mounting is available. The M2 FREEZER Door is recommended for inside environments with extremely cold temperatures not exposed to winds.
Colours
White
Blue
Grey
Yellow
Black
Orange
Red
Green
Standard Dimensions
15′ W x 15′ H
Opening Speed
96 in/s
Closing Speed
48 in/s
Operating Type
Gear driven, push-pull movement
Side Guide
Made of structural channels of 3 1/8” x 1 5/8” x 1/8” in galvanized steel. Protected by a layer of polyethylene in order to create a thermal barrier between the door frame and the structure of the building. Provided with heating-cables which prevent ice formation and assures the proper functioning of the door. Warning: In spite of the presence of heating cables, in some applications an accumulation of ice may occur. For safety reasons, removal of the ice on the door and the floor may be required.
Air Circulation Unit (Optional)
Can be mounted within the head unit to reduce frost and ice formation.
Inner Side Guide
Polyethylene (PE-UHMW 1000); outer section 7/8” x 1 9/16”, spring loaded, includes heating-cables which prevent ice formation within the side guides.
Side Guide Covers
Galvanized Steel
Drum
In steel, diameter 4″ x 0.078″, shafts in steel.
Door Curtain
Reinforced PVC (27 oz/sq.yd). Available in different colors and provided with stainless steel side sealing zippers (Section 5/8” x 1/2”); soft bottom edge design.
Motor
Without brake, with 4 poles, controlled by a variable speed drive. Power: 2 HP. Protection degree NEMA 4.
Motor Cover
Galvanized Steel
Gearbox
Size 63 for a motor of 2 HP and gear reduction ratio 1/7.
Detectors
An infrared photocell installed inside the side guide and detecting the presence of a pedestrian or a vehicle. Upon activation, it opens the door immediately and keeps it open as long as the presence is detected. Height of the photocell: 12” from the floor. (Optional: up to maximum 24” from the floor). A detector within the side guides reverses the door when it hits an obstacle during the closing cycle.
Power Supply
Standard: single phase 208-230 VAC, three phase 208-230 VAC, three phase 460 VAC. Optional: three phase 575 VAC. Frequency: 50-60 Hz. Fuses to be provided by the customer: 25 A for a motor of 2 HP.
Space Requirements
All indicated dimensions are net: the additional space necessary for mounting and maintenance has to be taken into account. Reduced dimensions upon request.
- Works in temperatures of up to -22 degrees
- Maximum standard dimensions 15′ x 15′ opening
- Operating Speed: 96″/sec. open, 48″/sec close
- Curtain made of reinforced PVC vinyl
- Heated side guides
- Berner unit available to minimize condensation and moisture
- Infrared photocell in side guides
- Soft bottom edge
- Pneumatic bottom edge detector
- Designed for interior or exterior cold storage, freezers, or processing to freezers
- Cold Storage
- Freezer Applications
- Processing to Freezer